Product Model |
Standard Model: TIC20 Extention Model: WHO-Type 1, WHO-Type 2, WHO-Type P and WHO-Type R |
Operating Temperature Range |
-30°C to +60°C |
Storage Temperature Range |
-30°C to +65°C |
Ambient humidity range during transport and use |
0 to 95%RH |
Resolution |
0.1°c or better in range of -30°C to +60°C |
Accuracy |
• Better than ±0.5°C for -10°C to +40°C • Better than ±1.0°C for -30°C to -10°C • Better than ±1.0°C for +40°C to +60°C |
Capacity |
• Minimum & Maximum temperature for each of the 20 days • 1st activation of each Alarm for each day including Trigger time and duration of each excursion |
Memory type |
Non volatile |
Sampling Interval |
Factory set to 6 minute interval (i.e 0.1hour) |
Logging modes |
20 day statistics, temperature/time excursions and Alarm trigger time and duration for each day |
Logging Start delay |
Factory set to 60 minute interval |
Sensor |
Precision thermistor |
Sensor Reaction time |
T90 less than 7 minutes by method detailed in EN12830:1999 |
Vibration |
Withstands vibration specification as detailed in EN12830:1999 |
Shock |
• Withstands shock specification as detailed in EN12830:1999 • Withstands 5 drops from 1m to smooth concrete floor without loss of function or calibration |
Environmental |
IEC 60529: IP64 |
Power source |
3V Lithium battery – non replaceable |
Battery life |
• Minimum storage life of 18 Months before ‘start’ • Monitoring period: 20 days • Minimum accessibility (display) period of 6 months after ‘stopped’ |
Size |
73mm(H) x 54.5mm(W) x 8.6mm(T) (Volume < 34cm3) |
Weight |
30g |
Case Material |
Polycarbonate |
Calibration |
Covered by Certificate of Traceability. Calibration traceable to an ISO/IEC 17025 accredited testing laboratory. |
EMC compliance |
• EC EMC directives (EN 61000-6-1:2005 & EN 61000-6-3:2006) • Includes electrostatic discharge as prescribed in EN 61000-4-2 • Complies with FCC Part 15 Subparts A and B |
Alarms function & display |
• Alarm functions as prescribed in the WHO PQS performance specification E06/TR07.2 • Alarms are displayed on a custom LCD • Display activates when any button is pressed • Display is static allowing photocopying |
Alarm type |
Temperature alarm threshold |
Period of exposure |
High threshold |
≥ 45°C |
1 hour of continuous exposure |
Medium threshold |
≥ 30°C |
10 hours of cumulative exposure |
Low threshold |
≤ -0.5°C |
1 hour of continuous exposure |
Type 1 Alarm version |
DTP, DT, TT, Td, HepB, IPV, liquid Hib, MenAfrivac, HPV and PCV vaccines. |
Type 2 Alarm version |
OPV, freeze-dried BCG, measles, MR, MMR, lyophylized Hib, yellow fever, meningitis, Rabies and Rotavirus vaccines. |
Type P Alarm version |
Prevenar 7 & 13 vaccines. |
Type R Alarm version |
RotaTeq® vaccines. |