UTRID-16 Display Temperature Logger

Product description

The LogTag® UTRID-16 provides a display to allow immediate viewing of current and past temperature and alarm statistics. The display shows recording status, current temperature, alarm status of up to six user-configurable alarms and duration of any temperature excursions.

Download

Product classification

Product Model
UTRID-16 (Replaceable Battery).
Sensor Measurement Range
-30°C to +60°C (-22°F to +140°F).
Operating Temperature Range
-30°C to +60°C (-22°F to +140°F).*
Storage Temperature Range
0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy
Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F).
Better than ±0.7°C (±1.3°F) for -25°C to -20°C (-13°F to -4°F) & +40°C to +60°C (+104°F to +140°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution
Less than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag.®
Sensor Reaction Time
Typically less than 7 minutes (T90) in moving air (1m/s) in EN12830:1999.
Recording Capacity
16,129 temperature readings. 56 days @ 5min logging, 168 days @ 15min logging.
Statistics memory (for display on LCD):Max/Min values and alarm duration values.
Sampling Interval
Configurable from 30 seconds to 18 hours.
Logging Start Options
Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time.
Recording Indication
“REC” symbol on LCD.
Download Time
Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental
IEC 60529: IP64 with USB cap fitted.
Power Source
3V CR2032 Battery (User replaceable).
Battery Life
Typically 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once

daily for no longer than 30 seconds each time, download data monthly) provided the logger is kept within the storage temperature

range when not in use.

The battery low symbol will appear on the LCD if the UTRID-16 has a low battery.
Real Time Clock
Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface
USB 2.0, A-type plug.
Software
PDF Reader, LogTag® Analyzer 2.8 or higher.
Size
93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight
39g.
Case Material
Polycarbonate.
Footnote

*(-30°C to +60 °C applies to Loggers with serial numbers 6x45x15811 or greater. Loggers with serial numbers prior to this have an

operating temperature range of -25°C to +60°C).

Compliance and Certifications

FDA CFR21 Part 11 FCC EMC Directive CE EMC Directives Conforms to RoHS




ACCESSORIES



Protective Enclosure Wall Mount