Product Model |
UTRID-16 (Replaceable Battery). |
Sensor Measurement Range |
-30°C to +60°C (-22°F to +140°F). |
Operating Temperature Range |
-30°C to +60°C (-22°F to +140°F). |
Storage Temperature Range |
0°C to +40°C (32°F to +104°F). |
Rated Temperature Reading Accuracy |
Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F). Better than ±0.7°C (±1.3°F) for -25°C to -20°C (-13°F to -4°F) & +40°C to +60°C (+104°F to +140°F). Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart above. Accuracy figures can be improved by recalibration. |
Rated Temperature Reading Resolution |
0.1°C (0.1°F). Please see the Rated Native Resolution chart below. LogTag Analyzer® currently displays to one decimal place of °C or °F. |
Sensor Reaction Time |
Typically less than 7 minutes (T90) in moving air (1m/s) in EN12830:1999. |
Recording Capacity |
16,129 temperature readings. 112 days @ 10min logging, 168 days @ 15min logging. Statistics memory (for display on LCD): Max/Min values and alarm duration values. |
Sampling Interval |
Configurable from 30 seconds to 18 hours. |
Logging Start Options |
Push button start or specific date & time. Optional start delay of up to 72 hours. |
Recording Indication |
“REC” symbol on LCD |
Alarms |
Three configurable upper and three configurable lower alarms. |
Download Time |
Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report. Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured) |
Environmental |
IEC 60529: IP64 with USB cap fitted. |
Power Source |
3V CR2032 Battery (User replaceable). |
Battery Life |
Typically 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer than 30 seconds each time, download data monthly) provided recorder is kept within the storage temperature range when not in use. The battery low symbol will appear on the LCD if the UTRID-16 has a low battery. |
Real Time Clock |
Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
Connection Interface |
USB 2.0, A-type plug. |
Software |
PDF Reader, LogTag® Analyzer 2.8 or higher. |
PDF Report |
One page report with trip and alarm summary. Multi-page report with list of readings, including date and time. |
Size |
93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap. |
Weight |
39g. |
Case Material |
Polycarbonate. |